RAM 4000 Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Audioverstärker RAM 4000 herunter. RAM 4000 Instruction manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 50
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
(AVM-BA48)
Instruction and Operations Manual
Refrigerated Vending Machine
Manufacturer:
Automated Vending Technologies, Inc.
Recommended Location:
This Refrigerated Vending Machine
Should Be Operated Indoors.
Please read the instruction
manual carefully before
use of the machine. Keep
this manual handy for
future reference.
RAM 4000
Seitenansicht 0
1 2 3 4 5 6 ... 49 50

Inhaltsverzeichnis

Seite 1 - Refrigerated Vending Machine

(AVM-BA48)Instruction and Operations ManualRefrigerated Vending MachineManufacturer:Automated Vending Technologies, Inc.Recommended Location:This Refr

Seite 2 - VENDING MACHINE

8 II Working Principle and the StructureThe RAM 4000 Vending Machine from AVT, Inc. comes standard with configurable trays and augers, especially d

Seite 3 - Warnings:

9Flow Chart:1 23456789CLEARENTER0Total AmountChange ChangeSTART Return KnobE N DBill insertCoin InsertKEY PAD Change ReturnDelivery BinChange outlet

Seite 4

10(II)StructureDisplay DoorLockDelivery BinBill ValidatorDisplayKey PadCoin InsertReturn KnobChange Retu rn

Seite 5

11 III Operating InstructionIn order to ensure successful daily operation of the RAM 4000 vending machine, the owner should

Seite 6 - Installation Requirements

12(I) ?The trays are tiltable. The tray will tilt down and stop at the limit position.(As shown in the Picture III). ? After loading products, lift t

Seite 7

13(III) INSTALLATION AND INSTRUCTION FOR THE BILL/COIN If not provided by AVT. Please refer to the owners manual for these products.(1)The fi

Seite 8 - Picture IV

14Picture lV(2)CONNECTION INSTRUCTIONS:Prepare a validator wire with three terminals (two are the same, the third one is different). For the two term

Seite 9 - Sketchmap of Indoor Grounding

15(IV) MACHINE START-UP1). Press the RESET button once. This button is located at the bottom right hand corner of the cabinet. 3). Make sure that t

Seite 10

16(V)The Locking and Unlocking of the Door1.Unlock the doorInsert the key, revolve the handle counter clockwise until the screw thread is completely

Seite 11 - Flow Chart:

17The LED display screen has three (3) different functions:1). In Retail. The Green light for retail indicates the machine is in use and able to con

Seite 12

VENDING MACHINEImportant Machine Placement Criteria andWarranty Information ……………………………………………………1Unpacking and Installation Instructions …………………………………

Seite 13 - Picture I

181.Function IntroductionThe operator can control and examine the vending machine by using the attached remote control to set the price, clock

Seite 14 - Picture III

19Step Operations Display Description 1 Press SALE STAT Once. 1. “TL” represents the total amount of the products. 2. “1234560” is the

Seite 15 - Tray No. and Price Tag

20(2)CHL SETThere are six lines of trays. The tray's number should be 11-18, 21-28,……61-68.Step Operation Display Description 1 Press CHL S

Seite 16

213 Press SET/START once Cancel the Set. After canceling the set the tray’s number will flicker. 4 Press SET/START twice Saving the Set. Aft

Seite 17

223 Press the keyboard to choose the tray number. 11 Choose No. 11 tray. Note: When the chosen tray No. does not set, the system

Seite 18 - ? Lock the door

2310 Press SET/START The selected coin pipe will begin to return coins until you press the FINISH button. 11 Press FINISH / Exit The R

Seite 19 - BILL IS OUT OF USE

24(5)Malfunction InquiryNote:1. If the machine is equipped with the Vend Sensing System (VSS), it will automatically detect if the product vended pro

Seite 20 - RAM 4000

25(6)SET SELLING WITH AWARDStep Operation Display Description 1 Press SALE MODE Once. It is in Force Vending Mode 2 Press UP or DOWN or FC

Seite 21 - (1) Sales Statistic

26(7) PARAMETER SET SYSTEM CLOCKStep Operation Display Description 1 Press MODE/STOP Once. It is in the system clock setting mode. 2 Press SET/STA

Seite 22 - 28,……61-68

278 Press SET/START Now you can set the hour and save the date’s setting. 9 Press UP or DOWN The range of hour is 0-23. 10 Press SET/START Now you

Seite 23 - (3)PRICE SET

The Security Matters Must Be Read Before InstallationYour safety and the safety of others are very important. We have provided many importa

Seite 24

28ENERGY-SAVINGStep Operation Display Description 1 Press MODE/STOP Twice Now it is in ENERGY-SAVING Mode. 2 Press SET/START The three fig

Seite 25 - (4)SALE TEST

29LAMP TIMEStep Operation Display Description 1 Press MODE/STOP Three times. Now you can set the ON/OFF Mode of the lamp. 2 Press SET/START

Seite 26 - is used to clear the

309 Press UP or DOWN The range is 00 59, use one minute as a unit. 10 Press FINISH / Save the settings for the OFF time of minutes an

Seite 27 - (6)SET SELLING WITH AWARD

314 Press FINISH / Save the setting and leave REFRIGERATION TEMP condition. MACHINE NUMBERStep Operation Display Description 1 Press MODE/

Seite 28

323 Press UP or DOWN The range for the first figure is 0-9,A-F. 4 Press SET/START The second figure flickering will allow you to assig

Seite 29

33Step Operation Indicator light Description 1 Press L ROOM once The green LED light on. The refrigeration is ON. 2 Press L ROOM twice The green L

Seite 30 - ENERGY-SAVING

34Malfunction Content List of AVM-BA48( Vending Machine):Malfunction Content Malfunction description GOOD The machine is working well. (There is no m

Seite 31 - LAMP TIME

USB GPRS USB GPRS USB GPRS USB GPRS Optional Parts No Yes No No No No Yes Yes Malfunction DisplayIt will display EA07, however, the

Seite 32 - REFRIGERATION TEMP

36After opening the door, please note:The machine will turn to remote control locked mode, if there is not any operation within 30 minutes. The

Seite 33 - 4 Press FINISH

It is necessary to conduct periodic maintenance on your vending machine in order to keep it in the best working condition possible.

Seite 34

21). Check polarity of the outlet you wish to use. It is important that the polarity is checked. If a problem exists with the socket it can cause ser

Seite 35

machine trays function properly.7). Coinage Maintenance Periodic lubrication of the transmission position will reduce friction to ensure flex

Seite 36

When Maintenance is Required on the Refrigeration Unit:If maintenance is required on the refrigeration unit, this can be done by following the steps b

Seite 37 - Malfunction Display

Attachment I Quick Troubleshooting GuideTroubles Reasons Solutions NO POWER 1. The socket doesn’t work. 2. The electrical plug is not in its r

Seite 38

Troubles Reasons Solutions No product is being delivered when inserting money. 1. The money is jammed. 2. The products are sold out. 3. The produ

Seite 39

Attachment II VENDING MACHINE SCHEMATICSBreakdown Drawing for the RAM 4000 Vending MachineREFRIGERATION SYSTEMDOORTRAYCHEST 42

Seite 40 - Condenser

The Breakdown Drawing of Chest Left Slide of the TrayInternal PartsDelivery Port PartsChest SeamFootUpper HingerLeft Side Board Port for Evaporator Ro

Seite 41

Double Paned GlassLockStainless Steel Control UnitsDisplayKey-PadReturn KnobCoin InsertChange OutletDelivery PortStainless Steel Delivery PortThe Br

Seite 42

The Breakdown Drawing of TrayTray Casing Seam AugersAugersSpring DriverElectrical Plug 45

Seite 43 - AVT parts

The Breakdown Drawing of the Refrigeration SystemBottom Board of CompressorMotor-CompressorScrew for GroundingVent-PipeWater BoxCondenser FanFan Tres

Seite 45

35). Check the fixed metal parts. Especially if there has been an earthquake of a 5.0 or higher or after machine has been moved from one location to

Seite 46 - The Breakdown Drawing of Door

Automated Vending Technologies, Inc.Corporate Office:341 Bonnie Circle, Suite 102 Corona, CA [email protected]

Seite 47

4(I)(1) Remove packaging materials.IMPORTANT: Do not remove any permanent instructions or the data label on your vending machine.Remove tape

Seite 48 - The Breakdown Drawing of

5(3) THE FIXATION OF THE BOTTOMMake sure the reliability of the floor surface (The minimum area is 43.5×41.3in.). While positioning, the detailed pro

Seite 49

6Note: a. The installation should be performed by trained technicians. b. The maximum angle of the machine is 15° when installing and in tra

Seite 50

7Sketchmap of Indoor GroundingGroundin g PortGroundin g Socket

Kommentare zu diesen Handbüchern